How vifs work in Data ONTAP
A virtual interface (vif) is a feature in Data ONTAP that implements link aggregation on your storage system. Vifs provide a mechanism to group together multiple network interfaces (links) into one logical interface (aggregate). After a vif is created, it is indistinguishable from a physical network interface.
The following figure shows four separate network interfaces, e3a, e3b, e3c, and e3d, before they are grouped into a vif.
Network interfaces before grouping
The following figure shows the four network interfaces grouped into a single vif called Trunk1.
Network interfaces after grouping
Different vendors refer to vifs by the following terms:
•
•
•
•
Vifs provide several advantages over individual network interfaces:
•
Multiple interfaces work as one interface.
•
If one interface in a vif goes down, your storage system stays connected to the network by using the other interfaces.
•
If the physical interfaces in a vif are connected to multiple switches and a switch goes down, your storage system stays connected to the network through the other switches.